Custom Search
 
  
 
TM 55-1905-219-14-5
3-62.2. VOLTAGE REGULATOR - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (Cont)
b. Screws
Remove
(1),
lock-
washers
(2), and
flat-
washers
(3)
c. Voltage
Remove.
regula-
tor (4)
NOTE
The following tests require a battery (12V) and a lamp (12V).
TEST
2.
a. Contin-
1. Clip one lead to the GEN.
uity of
terminal.
series
winding
2. Clip the other lead
The lamp should
to the BAT. terminal.
not light.
3. Close the cutout relay
The lamp should
contacts by hand.
light. If it
does not, re-
place regulator.
3-1124


 


Privacy Statement - Copyright Information. - Contact Us