Custom Search
 
  
 
TM 55-1905-219-14-5
3-62.2. VOLTAGE REGULATOR - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
TEST (Cont)
HOOK-UP FOR CHECKING CONTINUITY OF SERIES
WINDING. BULB SHOULD NOT LIGHT. BULB SHOULD
LIGHT WHEN CUTOUT RELAY CONTACTS ARE CLOSED
BY HAND. IF IT DOESN'T, REPLACE REGULATOR
b. Contin-
1. Clip one lead to the
uity of
GEN. terminal.
volt-
age reg-
2. Clip one lead to
The voltage reg-
ulator
the regulator base
ulator contacts
shunt
(ground).
should move.
If they do not,
replace the reg-
ulator.
HOOK-UP FOR CHECKING CONTINUITY OF VOLTAGE REGULATOR SHUNT WINDING.
VOLTAGE REGULATOR CONTACTS SHOULD MOVE.  IF THEY DO NOT,REPLACE THE
REGULATOR.