3-77. WATER MANIFOLD - MAINTENANCE INSTRUCTIONS.
Cooling water, leaving the cylinder head through an opening over each exhaust port, enters the water
manifold. The front section of the water manifold is connected to the thermostat housing. The aft section of
the water manifold contains a flexible by-pass hose to the exhaust manifold, where it will leave the exhaust
manifold and flows to the oil cooler.
This task covers:
a. Inspection
b. Remove
c. Installation
INITIAL SETUP :
Test Equipment
References
NONE
Para 3-75 Fresh Water Pump
Para 3-76 Expansion Tank and
Water Connection
Para 3-77 Thermostat and Housing
Equipment
Special Tools
Condition Condition Description
Para
NONE
NONE
Material/Parts
Special Environmental Conditions
Gasket, Kit P/N 5193113
Do not drain oil in bilges,
Gasket, Kit P/N 5193116
dispose of properly.
Personnel Required
General Safety Instructions
1
NONE
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1. Water
a. Water
1. Check for leaks.
manifold
manifold
outlet
2. Check for wear.
seal
3. Check for cracks or
breaks.