TM 55-1905-219-14-6
3-150. FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPLACEMENT (Cont)
c.
Outlet
1. Remove capscrews
flange
(7), and lock-
washers (8).
2. Remove outlet
Discard.
packing (9).
3. Remove outlet flange
(10) from fresh
water pump
outlet (11).
d.
Fresh
1. Remove bolts (12)
Use J4242
water
and seal washers
wrench to
(13).
loosen bolts.
2. Remove fresh water
pump (14) from
blower.
3.
Remove gasket (15).
Discard.
3-2597