TM 55-1905-219-14-6
3-150. FRESH WATER PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
4.
Fresh
a.
Outlet
1. Place the outlet
water
flange
flange (10) on
pump
fresh water pump
outlet (11).
2. Slip outlet pack-
Use repair kit
ing (9) over fresh
P/N 5193605.
water pump outlet
(11).
b.
Fresh
1. Install gasket (15).
Use repair kit
water
P/N 5193605.
Pump
2. Place fresh water
Align and mesh
pump (14) against
lugs on the
the blower end
drive coupling
plate.
with the lugs
on the inter-
mediate shaft
coupling.
3. Install seal washers
Tighten and
(13) and bolts (12).
secure to the
blower.
3-2598