TM 55-1905-219-14-9
4-39. MILK DISPENSER - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
ADJUSTMENTS (Cont)
in opposite direction in which indicating hand is to be moved until hand stands at proper
position.
c. Make this adjustment only after the cabinet temperature is 35 to 38 .
F
d. Replace flange ring and temperature indicator.
NOTE
Blue area of temperature indicator is FREEZE ZONE (below 32 ); green area
F
is SAFE ZONE (32 to 44 in increments of 2; red area is DANGER ZONE
F
F
)
(above 44 ).
F
REMOVAL
4. Milk
a. Power
Remove from source of
dispenser
cord
electrical power.
b. Milk can
Empty into sanitary con-
tainer.
c.
Door
Open.
d. Milk can
Remove.
(1)
e. Dispen-
Remove and disconnect.
sing tube
(2) and
well
valve 13)
f.
Mounting
Remove.
bolts
g. Milk
Remove.
dispenser
4-1014