e. The Coolant System is shown in Figure 1-44. Coolant is circulated through the engine by a centrifugal-type water
pump. Heat is removed from the coolant, which circulates in a closed system, by the heat exchanger. Control of the
engine temperature is accomplished by a thermostat which regulates the flow of the coolant within the cooling system.
Figure 1-44-. Coolant System
f. Engine starting is provided by an hydraulic starting system. Engine speed is controlled by an electrically controlled
hydraulic governor. The electric controls originate from the main switchboard.