TM 55-1905-220-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Item
Location Item to
Not Mission
No
Interval
Check/Service
Procedure
Capable If :
108
MONTHLY
Engine Room
LUBE OIL TRANSFFR PUMPR
Fails to
(FR 51)
function.
Add oil to shaft (2). Use oil
(MIL-L-9000H (SH)).
109
MONTHLY
Ramp Handling
BOW RAMP WINCH . Check
Low oil level.
Machinery
reducer oil level. Remove dipstick (6)
Compartment and check oil level.
Remove vent plug (7) to add gear oil
(MIL-L-2105D, GO 80/90) as
needed.
Lubricate pawl (8) with oil
(MIL-L-9000H (SH)) as needed.
Change 5