Custom Search
 
  
 
TM 55-1905-220-14-1
Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Item
Location Item to
Not Mission
No
Interval
Check/Service
Procedure
Capable If :
124
MONTHLY
Equipment and
SEWAGE AIR PUMP.
Repair
(2-40-0-A)
OIL SEPARATOR LEVEL. Check
Low oil level.
oil level in oil gage (6). To add oil,
remove pipe plug (7). Use oil
(MIL-L-9000H (SH)) (non-detergent).
PUMP OIL LEVELS. Check oil
Low oil level.
levels in sight valves (8). If oil is not
visible, check oil level on oil gage (6).
Add oil (MIL-L-9000H (SH))
(non-detergent). Purge system by
loosening fittings (9).
125
MONTHLY
Air Conditioning
Corroded or
Room
worn.
DRAINING. Drain water by opening
valves (6).
ZINC PROTECTORS. Remove
protectors (7), check for corrosion.
Clean with wire brush. Replace when
badly worn.
Change 5
2-181


 