Table 2-1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - continued
Location
Item
Item To Check/
Not Fully Mission
No
Interval
Service
Procedure
Capable If :
NOTE
183
Continued
Be sure strainer is free of
diesel oil before replacing.
Remove filler breather cap (3) and
refill hydraulic reservoir (1) with
hydraulic fluid.
NOTE
Hydraulic fluid used in the
pump unit is MIL-H-46170,
FRH, Type 1.
Replace filler breather cap (3).
Operate the system and maintain the
reservoir oil level.
CAUTION
Add hydraulic fluid to the
reservoir to maintain the
proper level as the system
fills. The reservoir holds 10
gallons (37.85 liters). The
system holds 30 gallons
(113.55 liters).
Continue to operate system to purge
air from the lines for smooth and
quiet operation.