TM 55-1905-220-14-10
5-7. VARIABLE SPEED MECHANICAL GOVERNOR - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
OVERHAUL - REASSEMBLY (Cont)
2. Apply a loctite
sealant grade HV or
equivalent to the
full 360 circum-
ference of the plug
and thread the plug
into the tapped end
of the governor
weight housing.
3. Tighten the plug to
45 lb-ft (61.0 Nm)
NOTE
Rotate the governor weight assembly. If a bind
exists, remove the housing plug and check to
see if the weight shaft bearing is fully seated in
the governor housing.
5-209