TM 55-1905-220-14-2
2-26. HYDRAULIC STARTING SYSTEM - ANCHOR WINCH COMPARTMENT.
Preliminary Adjustments.
a. Open shut off valve (1) by rotating valve counter-clockwise.
b. Open shut off valve (2) by rotating valve counter-clockwise.
c.
Operate hand pump (3) to charge accumulator (4).
d. Pressure gage (5) should read:
AMBIENT TEMPERATURE
GAGE READING
Above 40 (4.4 )
F
C
1500 psi (1054.5 kg sq cm)
40F to 0F (4.4C to -17.8 )
C
2500 psi (1757.5 kg sq cm)
Below 0 (-17.8 )
F
C
3300 psi (2319.9 kg sq cm)
2-27. HYDRAULIC STARTING SYSTEM - ANCHOR WINCH COMPARTMENT-SHUT DOWN.
In usual operating conditions, the hydraulic starting system, should not be shut down. The engines, when running,
maintain a constant pressure in the system.
a. Close all valves by rotating clockwise.
b. Note the pressure on the gages will remain constant.
2-351