TM 55-1905-220-14-2
2-65.
PRELIMINARY ADJUSTMENTS (Cont).
b.
Forward Engine Room.
(1)
Place the disconnect switch (1) to the ON position.
(2)
Press the START switch (2).
(3)
Observe the pressure gage (3) it should read 850 psi (5860.8 KPA).
(4)
Adjust pressure regulating valve (4) if the pressure is incorrect.
clockwise - increase pressure
counter-clockwise - reduce pressure
(5)
Operate directional control valves as required:
Do not operate directional control valves until securing devices have been released.
Refer to the following paragraphs to operate the following:
Anchor "A" frame valve (6) refer to para 2-68.
2-470
|
||