TM 55-1905-220-14-2
2-81. MAGAZINE SPRINKLER.
a. The magazine sprinkler is supplied with sea water from the firemain. In order to obtain sea water the fire pump
must be in operation. The sprinkler heads will operate when the temperature is high. In the pilot house on the alarm
panel are two magazine alarms. Sprinkler alarm will sound when there is no water available to the sprinkler heads. High
temperature alarm will sound when the temperature is high and the sprinkler heads are supplying water.
The fire pump must be supplying water to the firemains. Refer to paragraph 2-78 for fire pump operating instructions.
b
Equipment and Repair Parts Stores (2-40-0-A).
(1) Rotate valve (1) counter-clockwise.
(2) Remote control shutoff valve (2) is locked open (counter-clockwise).
2-518
|
||