Table 3-74. Anchor Winch Engine - Hydrostarter
Loss of Accumulator Precharge (Nitrogen) Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss of accumulator precharge (nitrogen) (Cont).
Step 2.
Check for defective air valve.
Release the pressure in the system by opening the relief valve on the side of the hand
pump. Then, loosen the hex lock nut on the nitrogen valve approximately 3/4 turn to
release the remaining precharge before attempting to remove the valve from the
accumulator. Replace the air valve. Refer to Direct Support Maintenance.
Step 3.
Check for damaged seal ring between shell and end cap.
Apply light oil on the threaded end of the accumulator at the end of the cap. Bubbling of
the oil indicates a leak past the end cap seal. Refer to Direct Support Maintenance.
Step 4.
Check for defective safety fuse.
Replace safety fuse assembly after releasing all nitrogen pressure.
3-216
|
||