Custom Search
 
  
 
TM 55-1905-220-14-3
Table 3-75. Anchor Winch Engine - Hydrostarter High Pressure
in System (3500 psi or above) Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
High pressure in system (3500 psi or above).
Step 1.
Check for defective gage.
Refer to Direct Support Maintenance.
Step 2.
Check for engine driven pump unloading valve not operating properly.
Overhaul the pump. Refer to paragraph 3-178.
Table 3-76. Anchor Winch Engine - Hydrostarter Fluid Emerges
from the Reservoir Filler Cap When Starter is Used Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Fluid emerges from the reservoir filler cap when starter is used.
Step 1.
Check for filter element in filler cap loaded with dirt.
Rinse the filler cap thoroughly in fuel oil and dry it with compressed air.
Step 2.
Check for nitrogen in fluid returned to reservoir.
Overhaul the accumulator. See table 3-74.
Step 3.
Check for excess fluid in reservoir.
Check the fluid level when the accumulator is empty. The fluid level should be
approximately 2-1/2 inches from the top of the tank.
3-217


 