3-52.3. HYDROSTARTER SOLENOID - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (Cont)
b. Remove screws (1) and
c. Remove housing from
mount.
REPAIR
9.
Repair.
Refer to Direct
housing
Support Mainte-
nance.
10.
Manual
a. Loosen wing nut (3).
control
screw
b. Unscrew manual control
screw (4) from solenoid
housing (5).
c. Remove lockwasher (6).
d. Remove wing nut (3).
e. Remove seal ring (7)
Discard seal
from manual control
ring.
screw (4).