Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-5
3-105. HYDROSTARTER PIPING (FORWARD ENGINE ROOM) - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (Cont)
7.
Reservoir
a. Check for leaks, dents
Refer to para-
(7)
or cracks.
graph 3-107. for
maintenance.
b. Check pipe connections
for leaks.
8.
Pressure
a. Check gage glass for
gage (8)
cracks or breaks.
b. Check fitting and con-
nections for tightness
and leaks.
9.
Accumula-
a. Check for leaks.
Refer to para-
tors (9)
graph 3-102. for
replacement and
to Direct Sup-
port Mainten-
ance for repair.
b. Check for dents or
cracks.
c. Check pipe connections
for leaks.
d. Make sure all fittings
are tight.
10.
Hydro-
a. Check for leaks.
Refer to para-
starter
graph 3-101 for
(10)
maintenance.
b. Check piping connec-
tions for leaks.
c. Check to see that the
return, supply and ac-
cumulator (pressure)
lines are tight.
3-1780
|
||