Tweet |
Custom Search
|
|
|
||
TM 55-1905-220-14-6
3-123.1. SLACK CABLE INTERLOCK LIMIT SWITCH - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
d. Contact
1. Install contact block
Check contact
block
(13) into housing
block alignment
(13)
(18).
.089/.078 in.
(.226/.198 cm)
DIM and .469 in.
(1.191 cm) DIM.
2. Install screws (17)
Torque screws
into contact block
to 4 to 6 in.
(13) and housing (18).
lbs. (.445 to
.683 Nm).
INSTALLATION
10.
Slack
a. Bottom
1. Install gasket (16).
cable
cover
inter-
(15)
2. Install bottom cover
Check alignment
lock
(15).
of screw holes.
limit
switch
(6)
3-2058
|
||