Custom Search
 
  
 
TM 55-1905-220-14-6
3-139.1. HYDRAULIC PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (Cont)
r. Thrust
1. Store the flat face.
plate
(24)
2. Air blow or wipe
clean.
3. Place a small amount
of grease into the
middle slot in the
thrust plate.
s. Pocket
Place a 29/64 inch
Use pocket seal
seal
(1.1509 cm) long pocket
K3026-4. Be
(26)
seal into the middle
sure the seal
slot.
is cut straight
across and the
seal is the
same length as
the slot.
3-2303


 