Custom Search
 
  
 
TM 55-1905-221-14-1
1-16.
ENGINE COOLING SYSTEM.
a.
Fresh Water Cooling Systems. These systems (fig. 1-6) provide cooling for the engines including the
exhaust manifolds. Water is circulated by the engine water pump through the engine and through the keel -mounted heat
exchanger. An expansion tank, with sight glass is included in each cooling system and is mounted in the engine room.
Check the water level daily as indicated in the sight glass.
Figure 1-6. Fresh Water Cooling System.
1-44


 