Table 5-1. Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC STARTING SYSTEM (Cont)
b. Replace shaft seal if inspectn reveals fluid is in housing.
io
3. Hydraulic starting motor turns, but engine does not.
Check for damaged or overrunning clutch.
Replace Bendix drive. Refer to paragraph 5-13.2.
4. Hand pump fails to charge system.
Check for damaged piston seal rings.
Remove, disassemble hand pump and replace defective seal rings.
5. Loss of accumulator precharge (nitrogen).
Step 1. Check for damaged piston or seal rings.
NOTE
Release all hydaulic pressure in the system
r
prior to performing any maintenance on the
accumulator.
a. Release nitrogen in accumulator.
b. Remove accumulator and disassemble.
c. Replace defective piston or sealing rings.
5-12


 