Tweet |
Custom Search
|
|
|
||
TM 55-1905-221-14-2
5-12.2.
ALTERNATOR (Continued)
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
d.
Remove the other two brush
holders as follows:
(1) Remove four brush
holder screws (34),
lockwashers (35),
two brush holder
screws (36), and
four brush springs
(37).
(2) Remove two brush
holders (38), and
brush holder spacer
plates (39) from
brush and stud
plate (40).
e.
Remove three screws (41), and
lockwashers (42) from brush
and stud plate (40).
f.
Remove brush and stud plate
(40) from commutator end
bracket (43).
g.
Remove terminal stud nuts
Remove only if
(44), lockwashers (45), plain
replacement of
washer (46), terminal stud
parts is
insulator (47), and insulated
required.
terminal stud bushing (48).
h.
To remove commutator end
Remove only if
bearing (49), remove expan-
replacement of
sion plug (50), pipe plug
bearing is
(51), wick (52), and press
required.
sleeve bearing (49) from
commutator end bracket (43).
5-187
|
||