Custom Search
 
  
 
TM 55-1905-221-14-2
5-13.3.
SOLENOID VALVE STARTING MOTOR CONTROL (Continued).
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1.
Accumulator
a.
Close accumulator valves.
Valves
The fluid pressure in the hydraulic starting system must be released
prior to servicing the engine-driven pump or other parts to prevent
possible injury to personnel or damage to equipment.
b.
Relieve pressure in lines.
2.
Electrical
Remove and tag electrical
Connections
connections (1 and 2).
3.
Hydraulic
a.
Remove hydraulic lines (3, 4,
Lines
and 5) from solenoid valve.
b.
Remove associated piping from
solenoid valve.
4.
Solenoid
a.
Remove nuts (6), washers (7),
Valve
(if used), and screws (8)
securing solenoid valve.
b.
Remove solenoid valve (9)
from mounting bracket (10).
5-224


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business