Tweet |
Custom Search
|
|
|
||
TM 55-1905-221-14-2
5-13.5.
ACCUMULATORS (Continued)
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1.
Close valve on opposite
accumulator.
WARNING
The fluid pressure in the system must be released prior to any
maintenance to the accumulator to prevent possible injury to personnel
or damage to equipment.
2.
Gage, Valve
a. Disconnect line (1) at valve
Cap open end.
and Piping
(2).
b. Remove valve (2) and nipple
(3).
c. Remove gage (4), and nipple
(5).
d. Remove tee (6).
3.
Accumulator
a. Remove nuts (7), lockwashers
(8), and screws (9) from
mounting brackets (10 and
11).
b. Remove accumulator (12) from
mounting brackets.
5-240
|
||