TM 55-1905-221-14-2
5-13.5.
ACCUMULATORS (Continued).
LOCATION/ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially
dangerous to personnel and property. Avoid repeated or prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100' 138'F (38' 59 ). Clean metal parts in cleaning solvent P-
C
D-680 and dry thoroughly.
INSPECTION
10.
a. Housing. Use a drop-light
to examine the bore of the
cylinder. The bore must be
smooth and free of scratches.
Check segment ring grooves.
b. Caps. Examine for damage.
Check fitting threads, valve
threads, and fuse holder
thread if holder has been
removed.
c. Piston. Examine for scratches
or scoring on O.D. The piston
must be checked in cylinder
to be sure it moves freely
throughout the entire length
of cylinder.
d. Air Valve. Examine threads
and replace if damaged.
Check for damaged valve seat.
e. Seal Rings. Inspect for
damage.
5-244