5-19. INJECTOR CONTROL TUBE (Continued).
LOCATION/ITEM
ACTION
REMARKS
ADJUSTMENT (Cont)
3. Adjust the load limit
screw locknut so the
bottom of the locknut
is 1-3/4 inch (4.45
cm) from the bottom
of the load limit
screw.
4. Loosen load limit
lever clamp bolts so
the lever is free to
turn on the injector
rack control tube.
5. Thread the load limit
screw into the
adjusting screw plate
until the locknut
"bottoms" against
the top of the
plate.
6. Hold the injector
rack control tube in
the FULL FUEL position,
and place the load
limit lever against
the bottom of the
load limit screw.
Then, tighten the
load limit lever
clamp bolts.
7. Check to ensure that
If necessary.
the injector racks
will just go into the
FULL-FUEL position-
readjust the load
limit lever.
5-437