5-21. HEAT EXCHANGER, THERMOSTAT AND HOUSING, HOSES AND CLAMPS -
ENGINE (Continued).
LOCATION/ ITEM
ACTION
REMARKS
REMOVAL (Cont)
f.
Slide hose clamps (7) and
hose (8) off of thermostat
housing outlet.
g. Remove capscrews (10),
lockwashers (11), and tube
clips (12) from overflow
tube (13).
h. Remove overflow tube (13).
Unscrew from
elbow.
i.
Remove sixteen capscrews
(14) and lockwashers (15).
j.
Remove heat exchanger (16).