5-25.
FRESH WATER PUMP (Continued).
LOCATION/ITEM
ACTION
REMARKS
INSTALLATION (Cont)
NOTE
Place pump assembly against blower cover so that lugs on drive
coupling mesh with lugs on intermediate shaft coupling.
c. Secure pump assembly (4) to
Use tool J4242
blower with bolt and seal
to tighten
assemblies (9).
bolts.
d. Slide packing (8), and
retainer (7) against the
cylinder block.
e. Secure with lockwashers
(6), and bolts (5).
f.
Install hose clamps (2), and
hose (3).
g. Close draincock (1).
h. Refill cooling system.
5-489


 