Custom Search
 
  
 
TM 55-1905-221-14-3
6-18.
ALTERNATOR (Continued).
LOCATION/ITEM
ACTION
REMARKS
TESTING (Cont)
b. Check negative rectifier diodes
with an ohmmeter. Connect negative
(-) ohmmeter probe to diode heat-
sink (1), and positive (+) probe
to each diode (2) terminal.
Resistance should be low or zero.
If resistance is high, diode is
defective.
c.
Check negative rectifier diodes as
specified in "b" above but with
ohmmeter leads reversed. Resis-
tance should be high or infinite.
If resistance is low, diode is
defective.
d. Check positive rectifier diodes
with an ohmmeter. Connect positive
(+) probe to diode heat-sink (3)
and negative (-) probe to each
diode (4) terminal. Resistance
should be low or zero. If resis-
tance is high, diode is defective.
6-209


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business