Custom Search
 
  
 
TM 55-1905-222-14
Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM
1. ALTERNATOR NOT CHARGING
Step 1.
Check to see if drive belts are loose or broken
Tighten alternator drive belts or replace as necessary
Step 2.
Check to see If alternator leads are secure
Secure alternator leads
Step 3.
Test to see if voltage regulator/voltage protector is defective (para. 3-5)
Notify unit maintenance
Step 4.
Test to see if alternator is defective (para. 3-5)
Notify unit maintenance.
2. ALTERNATOR OUTPUT LOW OR UNSTEADY
Step 1.
Check to see if drive belts are loose
Tighten alternator drive belts
Step 2.
Test to see if voltage regulator/voltage protector is defective.
Notify unit maintenance
Step 3.
Check to see if alternator brushes are worn or loose.
Notify unit maintenance
3. NOISY ALTERNATOR
Step 1.
Check to see If drive belts or pulley are loose
Tighten drive belts and pulley
Step 2.
Check for misaligned belts or pulley
Correct alignment