Custom Search
 
  
 
TM 55-1905-222-14
Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - Continued
Step 3.
Check for cracked or damaged housing
Notify unit maintenance
Step 4.
Check to see If drive belts are worn or defective
Notify unit maintenance
Step 5.
Check to see if alternator bearings are worn
Notify unit maintenance
4. BATTERIES WILL NOT HOLD CHARGE
Step 1.
Check to see if battery cables are loose or terminals are corroded
Clean and tighten as necessary
Step 2.
Check to see if battery water level is low
Add water
Step 3.
Test to see if batteries are defective
Notify unit maintenance
5. ELECTRICAL SWITCHES FAIL TO START ENGINE
Step 1.
Check to see if batteries are dead
Notify unit maintenance.
Step 2.
Check to see if wiring/switches are defective
Notify unit maintenance
Step 3.
Check to see if control valve solenoid is defective
Notify direct support maintenance
Step 4.
Check hydrostart accumulators for proper pressure
Step 5.
Check hydrostart valve alignment
Step 6
To isolate the problem to either the electrical or the hydraulic system, prepare to start the diesel and
depress the control valve solenoid manual release button If the engine starts It is an electrical
problem If no start, It is a hydraulic related problem