3-9 SERVICE RAMP SYSTEM RESERVOIR, STRAINERS AND FILTERS (Continued).
5. CLEAN RESERVOIR AND STRAINERS
a. Clean tank Inspection cover (10) with
a scraper
b. Close drain valve (11), temporarily
install cover (10) and use flushing
compound No 8509 (Spec AF-3595)
to flush the reservoir.
c. Drain flushing  compound, remove
tank inspection cover (10) and let dry
for one hour
d. Clean suction strainers (12) with wire
brush.
e. Clean the wire mesh screen on the
filler/breather-filter (13).
6. INSTALL STRAINERS, RESERVOIR
INSPECTION COVER AND FILLER/
BREATHER-FILTER
a. Install cleaned  suction strainers or
replacement  strainers in  reservoir
(12).
b Install filler/breather-filter (13).
c Install gasket (14) if in good condition
or Install a replacement gasket.
d. Install tank inspection cover (10) and
secure with capscrews (15).
e. Close drain valve (11) and fill ramp
reservoir (16) with hydraulic oil MIL-L-
17672.