Custom Search
 
  
 
TM 55-1905-222-14
MAINTENANCE OF FUEL SYSTEM
3-14 SERVICE FUEL STRAINER.
INITIAL SETUP
Tools:
Equipment Conditions
Tool Kit, Mechanic's, Rail
Engine shut down
and Marine
CLEAN FUEL STRAINER
NOTE
Clean the filter elements after every 500 hours of operation.
a.
To clean filter element number 2, set control
valve pointer (1) so that it is over indicated
number 1 on the valve gland (2). This shows
that clement number 2 is shut off.
b.
Turn cleaning handle (3) on top of element
number 2 one or more complete revolutions
(clockwise).
c.
Remove drain plug (4) and drain side of strainer
body into suitable container. Replace drain plug
(4).
NOTE
Step d is to be used when it is imperative to clean the strainers while
underway.
d.
Set control valve pointer (1) at arrow marked
BOTH on valve gland (2). This will permit strainer
body on number 2 element side to fill while number
1 element side is still operating so that at no time
will there be any stoppage of oil flow to the engine.
e.
Set control valve pointer (1) so that it is over
indicated number 2 on valve gland (2) and repeat
steps b, c, and d to clean element number 1.