Custom Search
 
  
 
TM 55-1905-222-14
4-28
REPLACE MSD PUMP AND MOTOR ASSEMBLY (Continued).
INSTALLATION
1. ASSEMBLE PUMP AND MOTOR.
a. Attach pump (11) to motor (12). Ensure that
motor shaft engages pump impeller.
b. Secure pump to motor with two stainless
steel screws (8), spacers (9) and washers (10).
2. INSTALL PUMP/MOTOR ASSEMBLY.
a. Install pump/motor assembly (3) on treatment
tank (7) Ensure mounting holes are aligned.
b. Secure pump/motor assembly (3) with four
screws (5) and washers (6).
3. RE-CONNECT TUBING ASSEMBLIES AND
WIRING.
a. Re-connect electrical wiring (4) to source of
power.
b. Install elbows (1 and 2) on inlet and outlet ports
of pump/motor assembly (3).
4-58


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business