Custom Search
 
  
 
TM 55-1905-222-14
4-31
SERVICE LEVEL INDICATOR (Continued).
d. Loosen clamps (6) or flag channel (7). Replace
clamps (6) or flag channel (7) if necessary.
2
REPLACE FLOAT AND FLAG CHANNEL
a. Install float (5) into housing assembly (4).
b. Install end cap (2) with a new 'O' ring (3) onto the
bottom end of housing assembly (4).
c. Secure end cap (2) to housing assembly (4)
with set screw (1). Tighten set screw (1) to 14-16
in /lbs.
d. Install flag channel (7) in the exact location on
housing assembly (4) as noted during removal.
e. Secure flag channel (7) with two clamps (6) and
tighten to 6-10 in./lbs. torque.
4-65


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business