TM 55-1905-222-14
MAINTENANCE OF RAMP HOISTING ASSEMBLY
4-31
SERVICE LEVEL INDICATOR.
Float assembly contains a magnet. Float should be inspected after tank cleaning or flushing to clean any metal
particles that may have attracted to magnet.
INITIAL SETUP
Tools:
Equipment Conditions:
Tool Kit, Mechanic's, Rail
Engine shut down
and Marine
Materials/Parts
General Safety Instructions
'O' Ring
Ensure that the reservoir is
P/N 2-218
drained completely before
removing float for cleaning
SERVICE
1.
REMOVE AND CLEAN FLOAT
a. Remove set screw (1) from end cap (2). Have
a container ready to catch oil.
b. Remove end cap (2) and 'O' ring (3) from
housing assembly (4). Discard 'O' ring If in bad
condition and replace.
c. Remove float (5) and clean thoroughly with a
clean lint-free cloth.
NOTE
Do not remove flag channel or clamps if replacement is not required. Observe and mark
flag channel position in relation to housing assembly and reservoir before removing.
4-64