TM 55-1905-222-14
5-22
REPLACE RAMP WINCH HYDRAULIC MOTOR (Continued).
CLEANING
CLEAN ALL REMOVED PARTS.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially
dangerous
to
personnel
and
property. Avoid repeated or
prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 100 - 138F (38- 59C).
a.
Wash all parts in cleaning solvent P-D-680.
b. Dry thoroughly with compressed air or clean
with lint-free cloths.
INSPECTION
INSPECT ALL REMOVED PARTS
a. Inspect and discard all preformed packings.
Get replacement packings.
b.
Inspect the base in the spring cover for
scores or bruises. Smooth out defects with
a scraper and extra fine emery cloth in
order that preformed packing will seal
effectively.
c. Check snap ring for flatness and that it
forms a true circle. Replace if bent or damaged.
5-52