5-41 REPAIR BILGE PUMP/HYDRAULIC MOTOR ASSEMBLY (Continued).
h. Install shaft assembly (21) into shaft sleeve
(16).
i.
Install drive clamps (8), bolts (7), lockwashers
(14) and nuts (13), but do not tighten.
j.
Tighten bolts (7) in the drive clamp (8)
assembly.
k. Rotate the drive shaft (29) slowly by hand to
make sure the impeller (15) does not rub or hit
the housing (2).
l.. Adjust impeller clearance if impeller (2) is
rubbing. Loosen bolts (7) in drive clamp
assembly. Move impeller either forward or
back. Use a screwdriver to move impeller (15)
back or move shaft sleeve (16) forward.
m. Install four capscrews (3) and lockwashers (4) to
secure the adapter (5) to the pedestal (6).
5-109
|
||