MAINTENANCE OF SEA WATER SYSTEM
5-42
REPLACE DUPLEX STRAINER (SEA WATER SYSTEM).
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Equipment Conditions
Tool Kit, Mechanic's, Rail
Engine shut down
and Marine
Seawater system drained
Seacock closed
REMOVAL
REMOVE DUPLEX STRAINER.
a. Close seawater seacock.
b. Open draincock (1) to drain strainers.
c. Loosen hose clamps (2) and slide back over
hoses (3).
d
Remove hoses (3).
e. Remove strainer (4) with associated piping
attached.
f.
Remove pipe section (5) from strainer (4).
g. Remove pipe section (6) from strainer (4).
INSTALLATION
INSTALL DUPLEX STRAINER.
a. Install pipe section (6) to strainer (4).
b. Install pipe section (5) to strainer (4).
5-110


 