Custom Search
 
  
 
TM 55-1905-222-14
5-47
REPLACE CONTROL VALVE (STARTING SYSTEM) (Continued).
INSTALLATION
INSTALL CONTROL VALVE
a. Install control valve (2) and secure with
mounting bolts (5).
b. With valve In place, torque bolts to 30-39 foot-
pounds (40 7-52 9 Nm).
c. Connect male connector (3) to control valve
discharge port. Connect reducing hex nipple (4)
to control valve inlet port
d. Remove tags and connect electrical leads (1).
e
Connect battery ground lead.
f
Pressurize system using hand pump.
g
Purge system of air and check connections
for leaks.