Custom Search
 
  
 
TM 55-1905-222-14
6-5 REPAIR ALTERNATOR (Continued).
ASSEMBLY
1
INSTALL NEW DIODES IN HEAT SINKS.
CAUTION
A heat dam must be used for diode protection when soldering or unsoldering
circuit leads to diode terminal. Grasp the diode connection terminal with
long nose pliers between diode and soldering iron.
Install new diode (45 or 46) in heat
sink and solder leads to diode
2
ASSEMBLE DIODES IN REAR HOUSING.
a
Assemble field diode (42), square and
round insulators (40 and 41),
regulator terminal carriage bolt (38),
positive and negative terminal
carriage bolts (39) and heat sinks
(43 and 44) as shown
b
Align and install diode assembly in
rear housing (6)
c. Secure diode assembly with flat
washer (36), lockwasher (35) and hex
nut (34)
d
Re-connect negative brush lead (33)
to negative heat sink (43) using
screw (32)
6-15


 