Custom Search
 
  
 
TM 55-1905-222-14
6-9
REPAIR RAMP LOCKING HYDRAULIC CYLINDER (Continued).
NOTE
Do not remove piston from piston rod unless parts are damaged or definite leakage has
occurred past the piston.
g. Remove rod seals (14), cushion ring assembly
(15), and barrel seal (16). Discard seals.
h. Remove piston cap (17), cushion ring assembly
(18), and piston (13).
i.
Remove piston OD seal (19). Discard seals.
j.
Remove return spring (20).
k. Remove breather plug (21).
CLEANING
CLEAN ALL PARTS
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially dangerous to personnel and property. Avoid repeated
or prolonged skin contact. Do not use near open flame or excessive heat. Flash point f solvent is 100 - 138F
o
(38 59C).
-
Clean all metal parts in solvent.
Place them on a clean surface and
dry thoroughly.
6-36


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business