REPAIR STEERING PUMP (Continued).
CAUTION
If the control valve is reversed in the counterbore, the unit will malfunction and
pressure will rise dangerously high.
o.
Install control valve (19) with the hex head
going first into the bore.
p.
Install a new 'O' ring (18) on plug (17) and slide
the plug into the cover (6). Press plug fully
and insert tapered pin (16) to retain the plug in
place.
Tap the tapered pin (16) to lock in
place.
q.
Install gasket (5).
Locate gasket on top of
cover mounting surface.
r.
Place manifold (4) over gasket (5) and align
holes to cover (6).
s.
Install copper washer (3) over screws (2)
and thread screws (2) into cover (6). Torque
to 90-100 lb in.
t.
Install copper washer (3) over screws (2)
and thread screws (2) into cover (6). Torque
to 90-100 lb in.