Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUSTED AS NECESSARY
AVAILABLE IF:
54
16-Ton 240V
Check compressor for leaks,
Class III leaks
unusual noises, and obvious
or unusual
damage.
noise.
55
Stern Anchor
Check fluid level, filter con-
Fluid is low,
l
l
l
Winch Hydraulic
dition and hydraulic pressure.
filter condi-
Fluid Tank
tion indicator
is in red or if
hydraulic pres-
sure exceeds
2000 psi.
CAUTION
Refer low fluid level, no
filtration, and excessive
hydraulic pressure readings to
unit maintenance.
56
Emergency
Generator
WARNING
The Manual, Automatic, Stop and
Off/Reset switch on the control
panel must be set at "Stop"
position when performing main-
tenance or repair work on a
standby generator set. This
prevents the unit from starting
if a power failure or voltage
drop should occur while working
on the unit. Failure to comply
could result in personnel
injury or death.
NOTE
The standby generator set may
not be needed very often, but
when it is, it is usually under
emergency conditions. Mainte-
nance of this standby unit is
essential. It must always be
maintained in excellent operat-
ing condition, ready to work
under load at any time.
2-239
|
||