Custom Search
 
  
 
TM 55-1905-223-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Service CONT
B Before
D During
A After
W Weekly
M- Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO.
B
D
A
W
M
INSPECTED
OR ADJUSTED AS NECESSARY
AVAILABLE IF:
Main Deck
Forward
NOTE
Not applicable to vessels with FM-
200 Fire Suppressant System
installed. Reference para. 2-46 and
2-47 for FM-200 and Water Wash-
down System operation. Ref. TM
55-1905-243-24&P for maintenance
and installation of FM-200
components.
Periodic inspections of the fire sup-
Paint Locker
72
pression system should be made to
HALON 1301
ensure efficient operation at all times.
Fire Suppres-
sion System
NOTES
During periods of extreme heat, fire
extinguishers may release a por-
tion of their charge through the
discharge nozzles. Visually inspect
nozzles for evidence of discharge
or leaks.
The two HALON 1301 fire suppres-
sion systems operate indepen-
dently and service the main engine
room and the paint locker. Each
system is designed to provide an
adequate amount of fire retardant
material for the space protected.
Check the system components to
System
ensure accidental damage to equip-
Components
ment has not occurred. Ensure cylin-
der straps are securely mounted.
Check for obstructions to the
Distribution
overhead discharge nozzles.
System
Ensure access to the extinguisher
Access and
assembly and all control pull boxes
Control
are unobstructed.
Boxes
Change 10


 