TM 55-1905-223-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUST AS NECESSARY
AVAILABLE IF:
81
Stern Anchor
Winch Hydraulic
Pump
Hydraulic Lines
Check hydraulic lines,
and Fittings
fittings, and controls for
leaks or obvious damage.
Fluid Level
Fluid level should be at the
Sight Glass
high mark. Top off as
required. Refer to LO 55-1905-
223-10.
Pressure Gauge
Pressure gauge should read
If reading is
2,900 psi or less.
above 2900 psi.
Filter Condition
Differential Pressure Gauge
If reading is
Indicator
should read less than 10 psi.
10 psi or
greater.
CAUTION
Refer low fluid level, no
filtration, and excessive
hydraulic pressure readings to
unit maintenance.
Engine Room
82
Engine Room and
Interior Hull
WARNING
Open the ventilators to ensure
hull compartments and engine
room are clear of fuel fumes.
Operate the blowers for at
least 5 minutes before starting
the engine.
Inspect the engine room and
Engine room is
interior hull for leaks.
taking on water
or Class III
leaks.
2-253