(b) Open SW-14, ISOLATION-MSD (4).
(c) Fill Chlorine Bleach Holding Tank (7).
(d) Open SEWAGE INLET VALVE (8).
(e) Ensure PL-1, BLACKWATER DIVERTER TO MSD or OVBD (6) and PL-2, GRAYWATER
DIVERTER TO MSD or OVBD (5) are aligned to flow to MSD.
(f) Open PL-4, OVBD DISCH (2) and PL-3, MSD-OVBD DISCH (3).
(2) At Marine Sanitation Device (FIGURE 2-117).
(a) Set DEMAND switch (2) to DEMAND position.
(b) Set BACKWASH switch (3) to WITHOUT BACKWASH position.
(c) Set NORMAL-RESET/DISABLE switch (1) to NORMAL position.
NOTE
If NORMAL-RESET/DISABLE switch (1) is in RESET/DISABLE
position, the unit will start to operate.
(d) On power panel P204 set circuit breaker 2 to ON position.
CAUTION
Red COMMODE WARNING LIGHT (4) must be off before flushing.
NOTE
COMMODE WARNING LIGHT is located in starboard companionway 01 deck.
2-10. Gyrocompass System.
a. Gyro Compass MARK 27 MOD 1.
NOTE
Gyro Compass startup procedure should begin at least 2 hours
before the compass is to be used to allow proper settling. The
compass should also have been stopped for a minimum of 1/2
hour before restarting.
(1) In Pilothouse, Power Panel EP103, set MK2T GYRO PWR CONV UNIT circuit breaker 1 to ON
position.
(2) On MK 37 MOD E Transmission Unit, set POWER switch (1, FIGURE 2-118) to UP position.
(3) On Gyro Compass MARK 27 MOD 1 Electronic Control Panel (FIGURE 2-119), set RPTR switch
(7) to OFF position.


 