Custom Search
 
  
 
TM 55-1905-223-10
2-11. Air Start Main Generator
.
a.
Align Fuel Oil Filter, Transfer, and Supply Piping System (FIGURE 2-124) totp enerator (air start)
or g
as follows:
(1) Open FO-36, DAY TK F-12P SUPPLY TO PORT MN ENG & SSDG (22).
(2) Open FO-32, SUPPLY TO PORT SSDG (27).
(3) Open FO-40, RETURN FR PORT SSDG TO DAY TK F-12P (26).
b.
Align SSDC Fresh Water Cooling Piping System (FIGURE 2-125).
(1) Open FWC-14, EXP TK-SSDG PORT (8).
(2) Position FWC-12, KEEL CLR/SSDG PORT CLG MODE SELECTOR (11) to port position.
(3) Open FWC-10, KEEL CLR INLET (10).
(4) Open FWC-8, KEEL CLR OUTLET (1).
c.
Align SSDG Compressed Air Piping System IGURE 2-126).
(1) Open LPA-12, SUPPLY TO SSDG PORT (27).
Change 2 2-368.4


 