FIGURE 2-143. TYPE-I Motor Switch.
(i)
Close all valves in Lube Oil Purification and Transfer Piping System
(6)
Start Port Main Engine.
(a) At Main Engine Control Panel (FIGURE 2-138), START AIR PRESSURE gauge
(3) needle indicates 125 psi.
(b) Set REMOTE START CUTOUT SWITCH (6) for local operation.
(c) Set POWER SWITCH EMERGENCY STOP (5) switch to UP position.
(d) Press PUSH TO START ENGINE START (4) pushbutton.
NOTE
Engine should start within 10 seconds.
(e) Release PUSH TO START ENGINE START (4) pushbutton.
(f)
Monitor ENGINE OIL PRESSURE gauge (1) (20 to 70 psi), ENGINE OIL TEMP
gauge (8) (175 to 195 ), and ENGINE WATER TEMP gauge (8) (160 to
F
F
F
203 ).